软土深埋大断面类矩形顶管结构受力分析与实测

    Mechanical analysis and field measurement of large-section quasi-rectangular pipe jacking buried deeply in soft soils

    • 摘要: 深埋大断面矩形及类矩形顶管越来越多应用于软土地铁车站等大型城市地下结构建设,该新型结构水土荷载特征及结构受力性能对保障城市地下空间长期安全具有重要作用,然而相关研究仍较为有限。本研究依托上海轨道交通14号线静安寺车站工程,结合现场实测与理论分析,研究了软土深埋大断面类矩形顶管结构水土压力与受力响应的空间分布特征,对比分析了不同土压力理论及土-结构相互作用模式对顶管结构内力响应的影响方式,开展了设计理论的适用性评估。主要结论为:①结构顶部竖向土压力的实测值接近土柱理论的计算值,且基于土柱土压力计算的结构弯矩与实测较为吻合,反映出本工程中顶管顶部土拱效应可能较弱;②类矩形顶管的弯矩呈“蝴蝶状”分布,表明结构变形模式为竖向内凹及横向外凸,其中横向外凸可进一步诱发地层水平抗力;③地层水平抗力对大断面类矩形顶管结构内力可产生显著影响,现有设计规范较多忽略这一因素,可导致结构弯矩被严重高估(如依托工程中顶管腰部弯矩的计算误差可达2倍)。

       

      Abstract: Deeply buried large-section rectangular and quasi-rectangular pipe jackings are increasingly used in the construction of large-scale urban underground structures such as subway stations in soft soils. The water and earth pressures and internal force responses of the structures can play an important role in ensuring the long-term safety of urban underground space. However, the relevant researches are still limited. Based on the field measurements of Jing'an Temple Station Project of Shanghai Metro Line 14, the spatial distribution of water and earth pressure and structural responses of large-section rectangular pipe-jacking structure deeply buried in soft soils are investigated. Then, the influences of earth pressure theories and soil-structure interaction modes on the internal force responses of pipe-jacking structures are analyzed. The applicability of different design methods are evaluated. The main conclusions include: (1) The measured vertical earth pressures at the top of the structures are close to the theoretical values of soil column weight, and the bending moments of the structures calculated by using the above theoretical earth pressure are consistent with the field measurements, and thus suggesting that the soil arching effects at the top of the pipe jacking in this project may not be significant. (2) The bending moment of the quasi-rectangular pipe jacking shows a "butterfly-shaped" distribution, indicating that the deformation mode of the structures is vertically concave and transversely convex, while the transverse convexity of the waist can further result in horizontal ground reactions. (3) The horizontal soil reactions can have significant impacts on the internal force of the large-section rectangular pipe jacking structures. The existing design specifications for pipe-jacking structures mostly ignore this factor, which can lead to a remarkable overestimation of the structural bending moment (e.g., for the structures in the case study, and the computation error for the bending moment at the waist areas can be a factor of two).

       

    /

    返回文章
    返回