Abstract:
To improve the thermal insulation and seismic performance of high-rock-temperature tunnels in strong seismic zones, a shake table model test method was employed to conduct a comparative study on the thermal insulation and seismic performance of three measures: no measures, a solid energy-absorbing layer, and an open-air-beam energy-absorbing layer. The results indicate that the temperature at the outer measurement point of the invert of the secondary lining structure on the monitoring surface within the thermal break decreased by 8.99°C for the open-air beam energy-absorbing layer measure and by 4.34°C for the solid energy-absorbing layer measure, with the former’s reduction being 2.07 times that of the latter; Under a 0.3g load condition, the tunnel lining in the no-measurement group exhibited cracking, while the tunnel linings in both the solid energy-absorbing layer and open-air-beam energy-absorbing layer groups exhibited cracking under a 0.4g load condition; The peak tensile and compressive strains exhibited a “first increase, then decrease” trend, with the highest strains occurring at the fault monitoring surface. The peak tensile strain of the open-air beam energy-absorbing layer was 86.94% of that in the unmodified group, indicating that the open-air beam energy-absorbing layer can effectively absorb energy and enhance the tunnel’s seismic resistance; A computational model for thermal insulation and seismic mitigation in high-rock-temperature tunnels was established. Its validity was verified through shake table model tests, and the design parameters of the open-air-beam energy-absorbing layer were optimized, with the optimal beam spacing determined to be 1.5:5. The research findings can serve as a reference for seismic and disaster-mitigation design in high-rock-temperature tunnels.