非饱和土强度参数随吸力的变化规律及其工程应用

    The variation of strength parameters of unsaturated soil with suction and its engineering application

    • 摘要: 两个强度参数(即内摩擦角和黏聚力)是确定土的抗剪强度的前提。为了搞清非饱和土两个强度参数随吸力的变化规律,分析了225个非饱和土三轴剪切试验和102个非饱和土直剪试验的破坏应力,发现各种非饱和土的黏聚力和内摩擦角都随吸力改变而变化,据此提出了描述非饱和土抗剪强度的新方法(CΦΜ),能够同时考虑吸力对非饱和土的黏聚力和内摩擦角两方面的影响;而有效应力法(ESM)和Fredlund建议的方法(FCM)将吸力的影响分别归结为摩擦作用和黏聚作用,都是片面的、不合理的;各种土的黏聚力都随吸力的增加而提高,而内摩擦角则随吸力的变化呈现多种形态,可归纳为8种类型;针对每种类型,分别构建了描述内摩擦角和黏聚力随吸力变化的数学表达式,二者共包含2~3个参数,便于应用。提出了分别用ESM、FCM和 CΦΜ计算非饱和土的土压力、临塑荷载、极限承载力和边坡稳定安全系数的理论表达式,为工程应用提供了科学依据。针对兰州理工大学一处原状Q3黄土陡坡台地,分别用ESM、FCM和 CΦΜ计算了该场地的土压力、临塑荷载、极限承载力和边坡稳定安全系数,发现在吸力较高时(相应的有效应力参数较小)用ESM计算结果与常识相悖,而用 CΦΜ计算结果与实测资料比较符合,同时说明了黄土地区很高的黄土柱和黄土壁屹立不倒的力学机理。

       

      Abstract: Two strength parameters (i.e., internal friction angle and cohesion) are prerequisites for determining the shear strength of soils. To clarify the variation patterns of these two strength parameters with suction for unsaturated soils, the failure stresses from 225 unsaturated soil triaxial shear tests and 102 unsaturated soil direct shear tests were analyzed. It was found that both the cohesion and internal friction angle of various unsaturated soils change with suction. Based on this, a new method ( CΦΜ ) for describing the shear strength of unsaturated soils was proposed, which can simultaneously consider the influence of suction on both the cohesion and internal friction angle of unsaturated soils. In contrast, the Effective Stress Method (ESM) and the method suggested by Fredlund (FCM) attribute the influence of suction solely to frictional effects and cohesive effects, respectively, which are one-sided and unreasonable. The cohesion of all soil types increases with increasing suction, while the internal friction angle exhibits various patterns of change with suction, which can be summarized into eight types. For each type, mathematical expressions describing the variation of internal friction angle and cohesion with suction were established, each containing only 2-3 parameters for ease of application. Theoretical expressions for calculating earth pressure, critical edge pressure, ultimate bearing capacity, and slope stability safety factors of unsaturated soils using ESM, FCM, and CΦΜ respectively were proposed, providing a scientific basis for engineering applications. For a steep slope terrace of intact Q3 loess at Lanzhou University of Technology, the earth pressure, critical edge pressure, ultimate bearing capacity, and slope stability safety factor at the site were calculated using ESM, FCM, and CΦΜ , respectively. It was found that at high suction levels (where the corresponding effective stress parameter is small), the calculation results using ESM contradicted common sense, while the results using CΦΜ were in good agreement with measured data. This also explains the mechanical mechanism behind the stable existence of very high loess columns and loess walls in loess regions.

       

    /

    返回文章
    返回