Analysis and calculation of reinforced structural foundation in frozen areas with thermosyphon
-
-
Abstract
Analysis and simulation was presented to calculate the capacity and temperature field of thermosyphons group in various arrangements. The result shows that the different arrangements lead to the different heat transferring capacity of a single thermosyphon and influence the underground temperature (the effect of reinforcing). The result can be used in the arrangement with optimized thermosyphon group in frozen areas.
-
-