Fireproof characteristics of lining and waterproof of shield tunnel with super-large diameter
-
摘要: 南京纬三路过江隧道处于高水压、软弱地层等情况下,火灾可能导致隧道衬砌及密封防水失效,使得隧道发生渗漏、涌水,对隧道造成毁灭性的灾害。采用有限元数值方法,对施工条件下、正常运营条件下无防护措施和有防护措施3种情况的衬砌管片进行火灾数值模拟。分析结果表明:施工状态下,止水带附近的温度在60℃以下,止水带处于安全状态;运营条件下,当无防火措施发生2 h火灾时,内侧止水带附近的最高温度接近300℃,止水带会被烧焦破坏;当有30 mm防火板保护发生2 h火灾时,止水带的最高温度保持在100℃之内,止水带安全。计算结果还表明,20 mm厚的防火板材在1 h的较大火灾的情况下能够保证结构的安全和止水带的安全,而30 mm厚的防火板能够在2 h的较大火情下保证结构的安全和止水带的安全。Abstract: The Weisan Road Yangtze River tunnel of Nanjing is under high water pressure and passes through weak stratum. Fire may cause the failure of lining and the waterproof, resulting in tunnel leakage and water gushing, and it may cause destructive disasters of the tunnel. Based on the FEM analysis, segments under fire and different conditions are simulated, including construction stage, normal operation condition without protective measures and normal operation conditions with protective measures. The analysis shows that, at construction stage, the temperature near the waterproof is below 60 ℃, and the waterproof is in a safe state. Under operating conditions without fire prevention measures, after fire of 2 h, the maximum temperature near the internal waterproof is close to 300 ℃, and the waterproof will be burned. Under the protection of 30 mm-fireproof board, after fire of 2 h, the maximum temperature of the waterproof can be controlled below 100 ℃, ensuring the safety of the waterproof. The 20 mm-fireproof board can ensure the structural safety and the waterproof safety for 1 h under larger fire case, and 30 mm-fireproof board can ensure the safety for 2 h.
-
Keywords:
- fireproof characteristic /
- shield tunnel /
- lining /
- waterproof
-
王松林,王 婷. 广深港高速铁路狮子洋隧道消防设计[J].(铁道标准设计), 2012(11): 79-84.(WANG Song-lin,WANG Ting. Fire protection design of Shiziyang Tunnel of Guangzhou-Shenzhen-Hongkong High-speed Railway[J]. Railway Standard Design, 2012(11): 79-84. (in Chinese))
朱合华,沈 奕,闫治国. 火灾下大直径盾构隧道结构力学特性有限元分析[J]. (地下空间与工程学报), 2012, 8(增刊1): 1609-1614.(ZHU He-hua,SHEN Yi,YAN Zhi-guo. Finite element analysis on mechanical properties of linings of large diameter shield tunnels under fire cases[J]. Chinese Journal of Underground Space and Engineering, 2012, 8(S1): 1609-1614. (in Chinese))
L?NNERMARK A,INGASON H. Gas temperature in heavy goods vehicle fires in tunnels[J].L?NNERMARK A, INGASON H. Gas temperature in heavy goods vehicle fires in tunnels[J]. Fire Safety Journal, 2005, 40: 506-527.
中交第二公路勘察设计研究院有限公司. 管片接缝防水可靠性试验及数值分析研究[R]. 武汉, 2012.(CCCC Second Highway Consultants Co Ltd. Test and numerical study on waterproof reliability of shield segments[R]. Wuhan, 2012. (in Chinese))
闫治国. 隧道衬砌结构火灾高温力学行为及耐火方法研究[D]. 上海: 同济大学, 2007.(YAN Zhi-guo. A study on mechanical behaviors and fireproof methods of tunnel lining structure during and after fire scenarios[D]. Shanghai: Tongji University, 2007. (in Chinese))