• 全国中文核心期刊
  • 中国科技核心期刊
  • 美国工程索引(EI)收录期刊
  • Scopus数据库收录期刊

裂缝对电渗模型尺寸效应影响的试验研究

温晓贵, 胡平川, 周建, 李一雯, 陶燕丽

温晓贵, 胡平川, 周建, 李一雯, 陶燕丽. 裂缝对电渗模型尺寸效应影响的试验研究[J]. 岩土工程学报, 2014, 36(11): 2054-2060. DOI: 10.11779/CJGE201411011
引用本文: 温晓贵, 胡平川, 周建, 李一雯, 陶燕丽. 裂缝对电渗模型尺寸效应影响的试验研究[J]. 岩土工程学报, 2014, 36(11): 2054-2060. DOI: 10.11779/CJGE201411011
WEN Xiao-gui, HU Ping-chuan, ZHOU Jian, LI Yi-wen, TAO Yan-li. Experimental research on influence of cracks on size effect of electro-osmosis model[J]. Chinese Journal of Geotechnical Engineering, 2014, 36(11): 2054-2060. DOI: 10.11779/CJGE201411011
Citation: WEN Xiao-gui, HU Ping-chuan, ZHOU Jian, LI Yi-wen, TAO Yan-li. Experimental research on influence of cracks on size effect of electro-osmosis model[J]. Chinese Journal of Geotechnical Engineering, 2014, 36(11): 2054-2060. DOI: 10.11779/CJGE201411011

裂缝对电渗模型尺寸效应影响的试验研究  English Version

基金项目: 国家自然科学基金项目(51478425); 浙江省滩涂围垦与岩土工程技术科技创新团队项目(2011R50020); 浙江省交通规划设计研究院科研项目(2013W03)
详细信息
    作者简介:

    温晓贵(1972-),男,博士,副教授,主要从事地基处理、软黏土力学、桩基工程等方面的教学与研究工作。E-mail:wenxiaogui@vip.sina.com。

Experimental research on influence of cracks on size effect of electro-osmosis model

  • 摘要: 通过对电渗-堆载模型试验、单纯电渗模型试验和现场试验的比较发现:裂缝发展的巨大差异是导致单纯电渗模型试验与现场情况差别较大的原因,适当的堆载可消除几何边界引起的尺寸效应,使试验裂缝开展较准确地反映了现场电渗的真实情况,其结果可更好地模拟现场电渗情况;消除尺寸效应后,影响电渗排水效果的主要因素是有效电场面积,电流密度仅为次要影响因素,在梅花形、长方形与平行错位三种布置形式中,有效面积占比最大的梅花形布置效果最优、经济性最好,建议实际工程中采用梅花形布置。
    Abstract: In order to study the size effect, a model experiment on the electro-osmosis combined with loading is designed and conducted. Through the comparison among model experiment on electro-osmosis combined with loading, model experiment on simple electro-osmosis and in-situ experiment on electro-osmosis, it is demonstrated that the large difference of cracks is the main reason why the model experiment on simple electro-osmosis draws an opposite conclusion with the in-situ experiment. The size effect caused by geometric boundary can be eliminated by reasonable loading, which makes the cracks similar to those in the in-situ experiment, so the model experiment on electro-osmosis combined with loading can better simulate the in-situ experiment. As the size effect is eliminated, the main factor influencing the electro-osmosis dewatering is the effective electric field rather than the current density. Among hexagonal, rectangular, and parallel and transposition configurations, the hexagonal configuration which has the maximum area of effective electric field is the most effective and economical, so it is recommended to be employed for electro-osmotic treatment.
  • [1] GLENDINNING S, LAMONT-BLACK J, JONES C J F P. Treatment of sewage sludge using electrokinetic geosynthetics[J]. Journal of Hazardous Materials, 2007, A139: 491-499.
    [2] 李一雯, 周 建, 龚晓南, 等. 电极布置形式对电渗效果影响的试验研究[J]. 岩土力学, 2013, 34(7): 1972-1978. (LI Yi-wen, ZHOU Jian, GONG Xiao-nan, et al. Experimental research on the effect of electrodes array to electro-osmotic dewatering[J]. Rock and Soil Mechanics, 2013, 34(7): 1972-1978. (in Chinese))
    [3] 王学滨, 刘 杰, 王 雷, 等. 基于梯度塑性本构理论的岩样侧向变形分析(II):尺寸效应及弹性回跳[J]. 岩土力学. 2004, 25(7): 1127-1130. (WANG Xue-bin, LIU Jie, WANG Lei, et al. Analysis of lateral deformation of rock specimen based on gradient-dependent plasticity(II): size effect and snap-back[J]. Rock and Soil Mechanics, 2004, 25(7): 1127-1130. (in Chinese))
    [4] ODA M A. Method for evaluating the representive elementary volume based on joint survey of rock mass[J]. Canadian Geotechnical Journal, 1998, 25(3): 281-287.
    [5] BAZANT Z P, DESMORAT R. Size effect in fiber or bar pullout with interface softening slip[J]. Journal of Engineering Mechanics, 1994, 120(9): 1945-1962.
    [6] WITTLE J Ke, ZANKO L M, FALK D, et al. Enhanced stabilization of dikes and levees using direct current technology[C]// Geocongress 2008: Geosustainability and Geohazard Mitigation. ASCE, 2008: 686-693.
    [7] FOURIE A B, JONES C J F P. Improved estimates of power consumption during dewatering of mine tailings using electrokinetic geosynthetics (EKGs)[J]. Geotextiles and Geomembrances, 2010, 28(2): 181-190.
    [8] ALSHAWABKEH A N, GALE R J, OZSU-ACAR E, et al. Optimization of 2-D electrode configuration for electrokinetic remediation[J]. Journal of Soil Contamination, 1999, 8(6): 617-635.
    [9] BAZANT Z P, XIANG Y Y. Size effect in compression fracture: splitting crack band propagation[J]. Journal of Engineering Mechanics, 1997, 123(2): 162-171.
    [10] CARPINTERI A, CHIAIA B. Multifractal scaling laws in the breaking behaviors of disordered materials[J]. Chaos, Solitons & Fractals, 1997, 8(2): 135-150.
计量
  • 文章访问数:  318
  • HTML全文浏览量:  3
  • PDF下载量:  336
  • 被引次数: 0
出版历程
  • 收稿日期:  2014-03-09
  • 发布日期:  2014-11-19

目录

    /

    返回文章
    返回